EM FIT 40/220...240/350 D CS L
- Small housing design
- Flexible current setting (DIPswitch 4 currents)
- High efficiency and reliability
- Enhanced safety due to overload, overtemperature, short-circuit protection
- High light quality due to low ripple current
- Long lasting and high reliability
- Linear and area lighting
- Shop lighting
- Offices, Public buildings, Supermarkets
- Industry lighting
- Suitable for luminaires of protection class I and II
Technical Data
Electrical data
Nominal input voltage
220 240 V
Mains frequency
50/60 Hz
Input voltage AC
198 264 V
Current set
DipSwitch
Power factor λ
≥ 0.95
Efficiency in full-load
90 %
Device power loss
5.0 W
Inrush current
50 A
Max. ECG no. on circuit breaker 10 A (B)
13
Max. ECG no. on circuit breaker 10 A (C)
23
Max. ECG no. on circuit breaker 16 A (B)
22
Max. ECG no. on circuit breaker 16 A (C)
36
Max. ECG no. on circuit breaker 25 A (B)
34
Max. ECG no. on circuit breaker 25 A (C)
57
Surge capability (L/N-Ground)
2 kV
Surge capability (L-N)
1 kV
Nominal output voltage
40 120 V
Nominal output current
200 / 250 / 300 / 350 mA
Output PSTLM
≤1
Output SVM
≤0.4
Nominal output power
8...42 W
Maximum output power
42 W
Output current tolerance
±7.5 %
Galvanic isolation
Non isolated
Total harmonic distortion
< 20 %
Output ripple current (100 Hz)
< 10 %
U-OUT (working voltage)
250 V
Dimensions & weight
Mounting hole spacing, length
200.0 mm
Product weight
130.00 g
Cable cross-section, input side
0.5 1.5 / 0.75 1.5 mm²
Cable cross-section, output side
0.5 1.5 / 0.75 1.5 mm²
Wire preparation length, input side
7 8 mm
Length
210.0 mm
Wire preparation length, output side
7 8 mm
Height
21.0 mm
Width
30.0 mm
Colors & materials
Casing material
Metal
Temperatures & operating conditions
Ambient temperature range
-20 +50 °C
Maximum temperature at tc test point
75 °C
Max.housing temperature in case of fault
110 °C
Temperature range at storage
-40 +85 °C
Permitted rel. humidity during operation
5 90 %
Lifespan
ECG lifetime
35000 / 50000 h
Temperature at the measuring point tc (°C) |
75 °C |
---|
Additional product data
Encapsulated
No
Capabilities
Dimmable
No
Overheating protection
Automatic reversible
Overload protection
Automatic reversible
Short-circuit protection
Automatic reversible
No-load proof
Yes
Intended for no-load operation
No
Max. cable length to lamp/LED module
2.0 m
Suitable for fixtures with prot. class
I
Number of channels
1
Programming
Box programming
No
Tuner4TRONIC
No
Tuner4TRONIC Field App
No
Programming device
DIPswitch
Certificates & standards
Approval marks approval
CE / ENEC / CCC / UKCA / RCM / EAC / TISI
Standards
Acc. to IEC 61000-3-2/Acc. to IEC 61347-1/Acc. to IEC 61347-2-13/Acc. to IEC 61547/Acc. to IEC 62384/CISPR 15/EN 55015
Type of protection
IP20
Logistical data
Commodity code
85044083900
Environmental information
Information according Art. 33 of EU Regulation (EC) 1907/2006 (REACh)
Date of Declaration
19-05-2023
Primary Article Identifier
4062172219914
Candidate List Substance 1
Lead
CAS No. of substance 1
7439-92-1
Safe Use Instruction
The identification of the Candidate List substance is sufficient to allow safe use of the article.
Declaration No. in SCIP database
0541bdcf-bacb-45f4-964f-41e51d4bf36f
Packaging information
EAN |
Unit |
Piece |
Dimension l x w x h |
Weight |
Volume |
---|---|---|---|---|---|
4062172219914 |
UNV
| 1 | 210mm x 30mm x 21mm | 130.00g | 0.13dm³ |
4062172219921 |
VS
| 20 | 375mm x 250mm x 75mm | 3034.00g | 7.03dm³ |
Downloads
Information about Family
- Line frequency: 50 Hz | 60 Hz
- Supply voltage: 220 240 V
- Lifetime: up to 50,000 h (temperature at Tc max. = -10 °C, max 10% failure rate)
- Wide output voltage range
- Fixed output (no dimming)
Intended for use with LED modules.
The forward voltage of the LED light source shall be within the defined operating window of the control gear in all operating conditions including dimming if applicable.
Separate control gear and light sources must be disposed of at certified disposal companies in accordance with Directive 2012/19/EU (WEEE) in the EU and with Waste Electrical and Electronic Equipment (WEEE) Regulations 2013 in the UK. For this purpose, collection points for recycling centres and take-back systems (CRSO) are available from retailers or private disposal companies, which accept separate control gear and light sources free of charge. In this way, raw materials are conserved and materials are recycled.
Products
Product |
|
|
|
|
|
Data sheet | ||
---|---|---|---|---|---|---|---|---|
EM FIT 18/220
240/350 D CS L
|
27...54 V | 200 / 250 / 300 / 350 mA | 210.0 mm | 30.0 mm | 21.0 mm | |||
EM FIT 40/220...240/350 D CS L
|
40 120 V | 200 / 250 / 300 / 350 mA | 210.0 mm | 30.0 mm | 21.0 mm | |||
EM FIT 60/220
240/350 D CS L
|
90 175 V | 200 / 250 / 300 / 350 mA | 210.0 mm | 30.0 mm | 21.0 mm | |||
EM FIT 75/220...240/550 D CS L
|
90 216 V | 350 / 400 / 500 / 550 mA | 210.0 mm | 30.0 mm | 21.0 mm |