HBO 2002 W/MA
Safety advice
Because of their high luminance, UV radiation and high internal pressure (when hot) HBO lamps may only be operated in enclosed lamp casings specially constructed for the purpose. Mercury is released if the lamp breaks. Special safety precautions must be taken. More information is available on request or can be found in the leaflet included with the lamp or in the operating instructions.
Technical Data
Electrical data
Nominal current
54 A
Nominal voltage
370 V
Type of current
DC
Rated wattage
200000 W
Nominal wattage
2000.00 W
Dimensions & weight
Diameter
620 mm
Length
2700 mm
Electrode gap cold
3.0 mm
Capabilities
Burning position
Other
Environmental information
Information according Art. 33 of EU Regulation (EC) 1907/2006 (REACh)
Date of Declaration
05-03-2024
Primary Article Identifier
4050300628240 | 4050300947259
Candidate List Substance 1
Lead
CAS No. of substance 1
7439-92-1
Safe Use Instruction
The identification of the Candidate List substance is sufficient to allow safe use of the article.
Declaration No. in SCIP database
af958d72-01f1-43c6-98a7-e4cb52024dea | d3ee2a8f-7201-41c8-8fe6-b8140950a0a3
Packaging information
EAN |
Unit |
Piece |
Dimension l x w x h |
Weight |
Volume |
---|---|---|---|---|---|
4050300628240 |
FS
| 1 | 589mm x 320mm x 230mm | 2656.00g | 43.35dm³ |
4050300732572 |
FS2
| 4 | |||
4050300628257 |
VS